AFS-1000 uses fluorescence immunoassay for quantitative detection to assist in the diagnosis and evaluation of various diseases such as inflammation, cardiovascul, renal injury and fertility.
AFS-1000 is a fluorescent immune series adaptation instrument. Insert the reagent card for automatic detection, completing the entire detection in one step (after inserting the card, the instrument automatically completes the entire process of detection, card abandonment, and reset (without the need for manual card removal)). Full touch, 7-inch 24 bit true color screen, connected to LIS - automatic sending of results, commonly used for detecting fluorescent immune series testing items.
Light weight (2.5kg), easy to carry
Automatic detection while insert reagent
Complete the entire detection process in one step
No need to manually pull out the cassette when the detection is completed
Full touch, 7-inch 24 bit color screen
Connect LIS - Automatically send results
Built-in thermal printer (suitable for 57mm thermal printing paper)
Model | AFS-1000 |
Screen | Full touch, 7-inch 24 bit color screen |
Test | Automatic recognition of product barcodes, effectively preventing errors |
Instrument Interface | Connect LIS - Automatically send results; USB drives |
Operate | After inserting the card, the instrument automatically completes the entire process of detection, card abandonment, and reset |
Size | 280*220*150(mm) |
Weight | 2.5kg |
Input | Input AC 110~240,50/60Hz |
Output | Output DC 24V/3A |
Built-in thermal printer (suitable for 57mm thermal printing paper) |
Detection Series | Test Items | Related Diseases | Sample Requirements | Detection Time | Determined Range |
Inflammation | hsCRP+CRP | Inflammation, cardiovascular disease | 5 μL serum/plasma 10 μL whole blood | 3 minutes | 0.5mg/L~200mg/L |
PCT | Inflammation, bacterial infection | 60 μL serum/plasma 70 μL whole blood | 15 minutes | 0.1ng/mL~100ng/mL | |
Cardiovasculor | NT-proBNP | Heart failure | 60 μL serum/plasma 70 μL whole blood | 15 minutes | 56pg/mL~35000pg/mL |
cTnI | Myocardial infarct | 60 μL serum/plasma 70 μL whole blood | 15 minutes | 0.2ng/mL~50 ng/mL | |
Kidney Disease | UmAlb | Impaired renal function | 60 μL urine sample | 15 minutes | 5mg/L~200mg/L |
CysC | Impaired renal function | 5 μL serum/plasma 10 μL whole blood | 15 minutes | 0.2mg/L~8.0mg/L | |
Fertility | AMH | Polycystic ovarian syndrome Premature ovarian failure | 60 μL serum/plasma | 15 minutes | 0.1ng/mL~23ng/mL |
AFS-1000 uses fluorescence immunoassay for quantitative detection to assist in the diagnosis and evaluation of various diseases such as inflammation, cardiovascul, renal injury and fertility.
Generally:
Air: 5-7 days, Ocean: 4-6 weeks
It can be saved with USB, printed by thermal printer which instrument equipped with, or access to LIS sytem.
Insert the reagent card for automatic detection, completing the entire detection in one step (after inserting the card, the instrument automatically completes the entire process of detection, card abandonment, and reset (without the need for manual card removal)).